TrippLite PDUB30 Dual source Power Distribution Unit - 100-127V, 24A, 5-15/20R, L5-30R
TrippLite PDUB30 Dual source Power Distribution Unit - 100-127V, 24A, 5-15/20R, L5-30R Description
TrippLite PDUB30 Dual source Power Distribution Unit
Tripp Lite�s PDUB30 Hot-swap PDU systems enable live-replacement of standard UPS systems for maintenance with no interruption of connected server or networking loads. Dual input power cables support PDU connection to separate Utility and UPS power sources. Manual transfer switch with lighted status indicators controls the source of power to connected equipment between Utility and UPS. Set the switch to UPS during normal operation and connected equipment will receive full-time conditioned power from the UPS. Set the switch to Utility to momentarily power connected equipment from the Utility line cord and bypass the UPS while the UPS system is removed and replaced with a fresh one. Once the new UPS is up and running with all data and electrical connections restored, set the switch back to the UPS setting to once again provide fully-conditioned UPS power to connected equipment.
What It Is And Why You Need It
- 2U rackmount hot-swap PDU enables live replacement of a standard UPS system without shutting down connected server and networking equipment
- Universally compatible with any Tripp Lite or other brand of 100-127V UPS up to 3000VA with a NEMA L5-30P input plug
- Manual transfer switch with lighted status indicators controls PDU output between Utility and UPS power sources
- 2U horizontal rackmount form factor compatible with 2 or 4 post racks
- Pair of attached 5-15P PDU input cables connect to separate Utility and UPS power sources
- 6 Built-in 5-15/20R and 1 L5-30R outlets continuously pass power to critical loads from selectable Utility or UPS input power sources
PDUB30 is universally compatible with any Tripp Lite or other brand of 100-127V UPS rated up to 3000VA with a NEMA L5-30P input plug. Pair of attached L5-30P PDU input cables connect to separate Utility and UPS power sources. 6 5-15/20R and 1 L5-30R outlets support critical networking loads in both Utilty and UPS operating modes. 2U rackmount installation in 2 or 4 post racks with support for space saving rear-post mounting in the same rack space as your Tripp Lite Rackmount UPS (select installations, see manual)
Features
- Tripp Lite Hot-swap PDU systems support live-replacement of standard UPS systems for maintenance with no interruption of connected server or networking loads
- PDUV30 is universally compatible with any Tripp Lite or other brand of 100-127V UPS rated up to 3000VA or 2880 watts with a NEMA L5-30P input cable
- 2U horizontal rackmount form factor compatible with 2 or 4 post racks
- Supports space saving rear-post mounting in the same rack space as many Tripp Lite Rackmount UPS systems (select installations, see manual)
- Pair of attached L5-30P PDU input cables connect to separate Utility and UPS power sources
- 6 5-15/20R and 1 L5-30R outlets support critical networking loads in both Utility and UPS operating modes
- One additional L5-30R pass-through outlet supports UPS input power cord
- Dual input power cables support PDU connection to separate Utility and UPS power sources
- Manual transfer switch with lighted status indicators controls the source of power to connected equipment between Utility and UPS
- Set the switch to UPS during normal operation and connected equipment will receive full-time conditioned power from the UPS
- Set the switch to Utility to bypass the UPS and provide connected equipment with unfiltered power directly from the Utility line cord while the UPS system is removed and replaced with a fresh one
- Once the new UPS is up and running with all connections restored, set the switch back to the UPS setting to once again provide fully-conditioned UPS power to connected equipment
What's Included
No comments: